LC-4C Amperometric Detector

[Picture of LC-4C]

The LC-4C is an analog detector specifically designed for LC/EC, with high current sensitivity, extensive filtering, offset and autozero. In addition to front panel controls, it can also be controlled from a PC using the ChromGraph software. One advantage of PC control is that it allows potential wave forms other than fixed potential to be applied to the cell (e.g., a triple pulse wave form for PAD applications).

There are 2 channels available on the LC-4C - the detector channel, which applies a potential and measures the current response, and the generator channel, which can apply a potential. The detector channel is used in all experiments, whereas the generator channel is only used in experiments in which analyte is electrolyzed before reaching the detector electrode; for example, dual series electrode applications. If the current on both channels needs to be recorded, two LC-4C detectors can be combined, or an LC-4C can used in combination with a Petite Ampere. Alternatively, up to 4 channels can be monitored using the LC epsilon detector.

 

Features

 

Specifications

Channels Generator and detector channels included.
Applied Potential Generator Channel: 0 ± 1.900 V
Detector Channel: 0 ± 1.999 V
Gain Generator Channel: 100 nA/V, 1.0 µA/V, 10 µA/V
Detector Channel: 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10, 20, 50, 100, 200, 500 nA/V and 1, 2, 5, 10, 20, 50 µA/V.
Filter Generator channel: One-pole filter, non-adjustable for each gain range
Detector Channel: Four-pole active filter with 14 settings (0.02, 0.03, 0.04, 0.05, 0.06, 0.08, 0.1, 0.15, 0.2, 0.3, 0.4, 0.5, 0.8, 1.0 Hz)
Manual Offset Detector Channel: 0-10, 0-100, 0-1000 nA

Autozero Detector Channel: Minimum of ± 20 times gain range setting.
The rezero point is adjustable to ± 30% of the full-scale setting.
Manual and autozero offsets can combine to extend range.
Output Generator Channel: Iout: 1 V (10 V Max.) on terminal strip.
Detector Channel: Iout: 1 V full scale (10 V Max.) and 10 mV full scale (100 mV Max.) are available on both banana jacks and the rear panel terminal strip.
Eout: Available on terminal strip.
Inputs 2 inputs on rear panel terminal strip for control of autozero and chart marker. Use with TTL low-level and switch closure outputs on autosamplers and integrators.
Control Connects to PC or ChromGraph DA-5 interface. Controls gain and filter on detector channel, cell on/off, autozero, and chart marker. Controls potential with ChromGraph software.
Power 100, 120, 220 or 240 VAC, 50/60 Hz, 120 Watts Max. Load

Amperometric Detectors

 

Accessories

 

EF-1015
LC-4C amperometric detector
EF-1015CZ
LC-4C amperometric detector modified for capillary electrophoresis
EW-8125
Single channel cell lead
EW-8114
Dual channel cell lead
EW-4462
DA-5 Control cable for 2 LC-4C detectors
EW-4374
Replacement generator electrode cell lead
EW-8110
Recorder lead (one per channel)